Machine technical sheet


Immagine rappresentane il macchinario
Brand: CEMONT
Model: BLUMIG 350 - Blumaster TF 300
Type: Arc welders
Power supply: Electrical (220V-380V)
Reference standard: UNI EN 12198-1
Classification according to standard IEC-EN 62471 / IEC-EN 60825-1: Non disponibile
Category according to standard EN12198-1 Non disponibile

SOURCE TECHNICAL SHEET
Type: arco elettrico - GMAW MIG
Emission: Continua
N. of lighting bodies: 1
Brand: filo continuo - gas Argon e CO2 su ferro
Model: 155 A gas Argon 98% flusso 13 l/min
Classification according to standard IEC-EN 62471 / IEC-EN 60825-1: Non disponibile
Reference standard: CEI 62-39

RELEVANT EMISSION TYPES  
                                       
            780 ÷ 3000 (IRA e IRB)    
            780 ÷ 1400 (IRA)                    
        380 ÷ 1400
(Visible and IRA)
                   
      315 ÷ 400
(UVA)
                             
    300 ÷ 700
(Blue light)
                             
  180 ÷ 400
(UVA, UVB e UVC)
                             
⇐ BAND ⇒    
Main protection measures to implement for safety purposes:
  1. Operators should protect their eyes and skin
  2. Isolating the work area with opaque screens; workers operating within the work area must use PPEs
  3. In order to assess the emissions, refer to the following machine in the database: CEMONT BLU MIG 350

Measurements in the field (Click to view the measurements in the field)

Reference person:
AUSL 7 Siena - Laboratorio Agenti Fisici Andrea Bogi ([email protected])

Rif.D.lgs 81/08 SPECTRAL RANGE TARGET ORGANS RESULT Val.
a ES (Ultraviolet) Eyes and skin Maggiore del VLE 2.5 W m-2
b EUVA (Ultraviolet A) Eyes Maggiore del VLE 2.29 W m-2
c,d LB (Blue light, extended source) Eyes Non disponibile
e,f EB (Blue light, small source) Eyes Maggiore del VLE 1 W / m2
  LAFA (Blue light, extended source, aphakic individuals) Eyes Non disponibile
  EAFA (Blue light, small source,aphakic individuals) Eyes Non disponibile
g,h,i L R (Visible and Infrared A) Eyes Irrilevante
j,k,l L R (Infrared A) Eyes Irrilevante
m,n EIR (Infrared A + Infrared B) Eyes Irrilevante
o Eskin (Visible + Infrared A + Infrared B) Skin Irrilevante
SENSOR-SOURCE DISTANCE
95
cm
MAXIMUM EXPOSURE TIME
11
seconds
SAFETY RADIAL DISTANCE
4200
cm