Machine technical sheet


Immagine rappresentane il macchinario
Brand: AGUSTA WESTLAND
Model: nh 500D
Type: Helicopter aircraft
Built in: 1976
Weight: 1361 kg
Power: 313 kW
Power supply: Aeronautical engine
Immagine rappresentante la tipologia
Declared values as set forth in the standard UNI ISO 2631-1:2014
CONDITIONS MATERIAL K(1)
No declared data
(1) Expanded uncertainty

Measurements in the field (Click to view the measurements in the field)


Referente: Vibrazioni - INAIL
Nome: Settore Ricerca, Dipartimento di Medicina, Epidemiologia, Igiene del Lavoro ed Ambientale
Location: Rieti

Ground / road type: IRRELEVANT
Ground / road conditions: IRRELEVANT
Forward speed (IN ITALIAN): NON INDICATA
SEDILE
Seat type: NON INDICATO
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: NON INDICATA
Potential adjustments of the seat: NON INDICATO
Armrests: Assenti
Conditions of measurement
Conditions of measurement
Accelerometer mounting

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.5 m/s2
dev. std. x 1,645:
0 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.05 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.5 m/s2
x 1.4
0.1 m/s2
X 1.4
0.2 m/s2
x 1
0.5 m/s2
a wv max
0.5 m/s2

Referente: Vibrazioni - INAIL
Nome: Settore Ricerca, Dipartimento di Medicina, Epidemiologia, Igiene del Lavoro ed Ambientale
Location: Rieti

Ground / road type: IRRELEVANT
Ground / road conditions: IRRELEVANT
Forward speed (IN ITALIAN): veloce
SEDILE
Seat type: NON INDICATO
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: NON INDICATA
Potential adjustments of the seat: NON INDICATO
Armrests: Assenti
Conditions of measurement
Conditions of measurement
Accelerometer mounting

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.3 m/s2
dev. std. x 1,645:
0.02 m/s2
dev. std. x 1,645:
0.02 m/s2
dev. std. x 1,645:
0.14 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.5 m/s2
x 1.4
0.2 m/s2
X 1.4
0.2 m/s2
x 1
0.5 m/s2
a wv max
0.5 m/s2

Referente: Vibrazioni - INAIL
Nome: Settore Ricerca, Dipartimento di Medicina, Epidemiologia, Igiene del Lavoro ed Ambientale
Location: Rieti

Ground / road type: IRRELEVANT
Ground / road conditions: IRRELEVANT
Forward speed (IN ITALIAN): NON INDICATA
SEDILE
Seat type: NON INDICATO
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: NON INDICATA
Potential adjustments of the seat: NON INDICATO
Armrests: Assenti
Conditions of measurement
Conditions of measurement
Accelerometer mounting

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.4 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0.09 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.5 m/s2
x 1.4
0.2 m/s2
X 1.4
0.2 m/s2
x 1
0.5 m/s2
a wv max
0.5 m/s2

Referente: Vibrazioni - INAIL
Nome: Settore Ricerca, Dipartimento di Medicina, Epidemiologia, Igiene del Lavoro ed Ambientale
Location: Rieti

Ground / road type: IRRELEVANT
Ground / road conditions: IRRELEVANT
Forward speed (IN ITALIAN): NON INDICATA
SEDILE
Seat type: NON INDICATO
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: NON INDICATA
Potential adjustments of the seat: NON INDICATO
Armrests: Assenti
Conditions of measurement
Conditions of measurement
Accelerometer mounting

Values related to the vibration worst case position: sedile
a wx (Mean):
0 m/s2
a wy (Mean)
0 m/s2
a wz (Mean)
0.1 m/s2
dev. std. x 1,645:
0 m/s2
dev. std. x 1,645:
0 m/s2
dev. std. x 1,645:
0.01 m/s2
Mean
+ (dev. std. x 1,645):
0 m/s2
Mean
+ (dev. std. x 1,645):
0 m/s2
Mean
+ (dev. std. x 1,645):
0.2 m/s2
x 1.4
0.1 m/s2
X 1.4
0 m/s2
x 1
0.2 m/s2
a wv max
0.2 m/s2

Referente: Vibrazioni - INAIL
Nome: Settore Ricerca, Dipartimento di Medicina, Epidemiologia, Igiene del Lavoro ed Ambientale
Location: Rieti

Ground / road type: IRRELEVANT
Ground / road conditions: IRRELEVANT
Forward speed (IN ITALIAN): moderata
SEDILE
Seat type: NON INDICATO
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: NON INDICATA
Potential adjustments of the seat: NON INDICATO
Armrests: Assenti
Conditions of measurement
Conditions of measurement
Accelerometer mounting

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.3 m/s2
dev. std. x 1,645:
0.05 m/s2
dev. std. x 1,645:
0.08 m/s2
dev. std. x 1,645:
0.08 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.2 m/s2
Mean
+ (dev. std. x 1,645):
0.4 m/s2
x 1.4
0.2 m/s2
X 1.4
0.3 m/s2
x 1
0.4 m/s2
a wv max
0.4 m/s2

Referente: Vibrazioni - INAIL
Nome: Settore Ricerca, Dipartimento di Medicina, Epidemiologia, Igiene del Lavoro ed Ambientale
Location: Rieti

Ground / road type: IRRELEVANT
Ground / road conditions: IRRELEVANT
Forward speed (IN ITALIAN): NON INDICATA
SEDILE
Seat type: NON INDICATO
Seat brand: NON DISPONIBILE
Seat model: NON DISPONIBILE
Seat suspension type: NON INDICATA
Potential adjustments of the seat: NON INDICATO
Armrests: Assenti
Conditions of measurement
Conditions of measurement
Accelerometer mounting

Values related to the vibration worst case position: sedile
a wx (Mean):
0.1 m/s2
a wy (Mean)
0.1 m/s2
a wz (Mean)
0.3 m/s2
dev. std. x 1,645:
0.01 m/s2
dev. std. x 1,645:
0 m/s2
dev. std. x 1,645:
0.05 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.1 m/s2
Mean
+ (dev. std. x 1,645):
0.4 m/s2
x 1.4
0.1 m/s2
X 1.4
0.1 m/s2
x 1
0.4 m/s2
a wv max
0.4 m/s2
logo regione toscana
Regione Toscana
Diritti Valori Innovazione Sostenibilità
collegamento sito usl 7 siena Servizio Sanitario
della
Toscana